Calculate operational parameters for Berlin-Schoenerlinde
Source:R/calculate_operational_parameters_berlin_s.R
calculate_operational_parameters_berlin_s.Rd
Calculate operational parameters for Berlin-Schoenerlinde
Usage
calculate_operational_parameters_berlin_s(
df,
calc_list = get_calc_info_from_config(config, "expr"),
calc_list_name = get_calc_info_from_config(config, "name"),
calc_list_unit = get_calc_info_from_config(config, "unit"),
calc_paras = get_calc_info_from_config(config, "paras"),
config = get_calc_config("berlin_s")
)
Arguments
- df
a data frame as retrieved by read_wedeco_data()
- calc_list
list with calculation operations to be carried out (default: list(deltaSAK = "(1-SCAN_SAK_Ablauf/SCAN_SAK_Zulauf)*100", Ozoneintrag = "(C_O3_Zugas - C_O3_Abgas)*Q_Gas/Q_Ozonanlage"))
- calc_list_name
full names of parameters to be used for plotting for each calculation specified wit 'calc_list'. default: c('delta SAK', 'Ozoneintrag')
- calc_list_unit
units of parameters to be used for plotting for each calculation specified wit 'calc_list'. default: c("percent", "mg-O3/L")
- calc_paras
a vector with parameter codes used for performing calculations defined in 'calc_list' (default: c("SCAN_SAK_Ablauf", "SCAN_SAK_Zulauf", "C_O3_Zugas", "C_O3_Abgas", "Q_Gas", "Q_Ozonanlage"))
- config
configuration object (list) from which the
calc_*
arguments are filled. Default:get_calc_config("berlin_s")
Examples
if (FALSE) {
raw_list <- read_wedeco_data()
myDat <- calculate_operational_parameters_berlin_s(df = raw_list)
}