R/calculate_operational_parameters_berlin_s.R
calculate_operational_parameters_berlin_s.Rd
Calculate operational parameters for Berlin-Schoenerlinde
calculate_operational_parameters_berlin_s( df, calc_list = list(deltaSAK = "(1-SCAN_SAK_Ablauf/SCAN_SAK_Zulauf)*100", Ozoneintrag = "(C_O3_Zugas - C_O3_Abgas)*Q_Gas/Q_Ozonanlage"), calc_list_name = c("delta SAK", "Ozoneintrag"), calc_list_unit = c("%", "mg-O3/L"), calc_paras = c("SCAN_SAK_Ablauf", "SCAN_SAK_Zulauf", "C_O3_Zugas", "C_O3_Abgas", "Q_Gas", "Q_Ozonanlage") )
df | a data frame as retrieved by read_wedeco_data() |
---|---|
calc_list | list with calculation operations to be carried out (default: list(deltaSAK = "(1-SCAN_SAK_Ablauf/SCAN_SAK_Zulauf)*100", Ozoneintrag = "(C_O3_Zugas - C_O3_Abgas)*Q_Gas/Q_Ozonanlage")) |
calc_list_name | full names of parameters to be used for plotting for each calculation specified wit 'calc_list'. default: c('delta SAK', 'Ozoneintrag') |
calc_list_unit | units of parameters to be used for plotting for each calculation specified wit 'calc_list'. default: c("percent", "mg-O3/L") |
calc_paras | a vector with parameter codes used for performing calculations defined in 'calc_list' (default: c("SCAN_SAK_Ablauf", "SCAN_SAK_Zulauf", "C_O3_Zugas", "C_O3_Abgas", "Q_Gas", "Q_Ozonanlage")) |
dataframe with calculated operational parameters
if (FALSE) { raw_list <- read_wedeco_data() myDat <- calculate_operational_parameters_berlin_s(df = raw_list)}